SICK VTB18-0P0240S01 is a cylindrical V18 diffuse-reflection photoelectric sensor with an 18 mm × 18 mm × 79.4 mm housing, M18 × 1 threading, and an axial optical axis. Its sensing range is adjustable from 30 mm to 92 mm, with detection up to 92 mm for objects offering about 90% remission (DIN 5033), and it emits visible red light at 660 nm with a light spot approximately 3 mm in diameter at 90 mm. The unit uses a 270° potentiometer for range adjustment, red-sealed to date code 1025, and has an average service life of about 100,000 hours at +25 °C. The 6032862 ordering information identifies this model as the VTB18-0P0240S01 variant, with PNP switching output listed in distributor catalogs.